Novec 1230 Fire Suppression System, Design
and Installation in Saudi Arabia

Fire suppressed in under ten seconds, with zero residue, water damage, or oxygen
depletion protecting critical assets without compromise. With a Global Warming
Potential of just 1, Novec 1230 is the clean agent of choice for ESG-driven and
green-certified facilities. Engineered to NFPA 2001 and accepted by Saudi Civil
Defense across the Kingdom.




Novec 1230 is a clean agent fire suppression system using FK-5-1-12 fluid to extinguish fire within ten seconds without residue, water damage, or oxygen depletion. With a Global Warming Potential of just 1 and an atmospheric lifetime of approximately five days, the Novec 1230 suppression system saudi arabia specification is the preferred choice for organisations with environmental sustainability requirements, ESG reporting obligations, or facilities targeting green building certification.

Multi Goals designs, supplies, installs, and maintains Novec 1230 suppression systems across Saudi Arabia. Every system is engineered to NFPA 2001, the Standard on Clean Agent Fire Extinguishing Systems, and includes mandatory room integrity testing as a standard commissioning step. Saudi Civil Defense accepts Novec 1230 systems for data centres, server rooms, control rooms, archive vaults, and telecommunications equipment rooms across the Kingdom.

Novec 1230 achieves fire suppression at a design concentration of approximately 4.2 percent by volume for Class A surface fires, which is lower than FM200 for the same hazard class. The lower required concentration means less agent by weight for the same protected volume, which typically results in fewer cylinders for equivalent protection compared to FM200 installations.

Get a Quote

Where Novec 1230 Suppression Systems Are Specified

Where Novec 1230 Suppression Systems Are Specified

  • Data centres and server rooms where zero-residue suppression and environmental credentials are both required
  • Telecommunications rooms and network equipment spaces in commercial towers and government buildings
  • Control rooms and electrical switchgear in industrial and oil and gas facilities
  • Archive vaults and document storage areas where water or powder suppression would destroy stored records
  • Museum and heritage collections requiring clean suppression without secondary damage risk
  • LEED-certified buildings where the environmental profile of all installed systems contributes to certification points

How Novec 1230 Works

Novec 1230 is stored as a liquid in cylinders under nitrogen pressure. On fire detection, the control panel initiates a pre-discharge alarm sequence giving building occupants a minimum 30-second warning to evacuate before agent discharge begins. This pre-discharge delay is mandatory under NFPA 2001. When the solenoid valve opens, the agent discharges through a calculated pipe network and nozzles positioned to distribute it evenly throughout the protected volume. Novec 1230 achieves fire suppression primarily by extracting heat energy from the flame at a rate faster than the combustion reaction can maintain. It transitions from liquid to vapour during discharge, absorbing large quantities of heat and suppressing the fire within ten seconds.

How Novec 1230 Works
Environmental Profile, Why It Matters in Saudi Arabia

Environmental Profile, Why It Matters in Saudi Arabia

Novec 1230 has a Global Warming Potential of 1 compared to carbon dioxide, and an atmospheric lifetime of approximately five days. In contrast, FM200 has a GWP of 3,350 and an atmospheric lifetime of 31 to 40 years. For organisations in Saudi Arabia with parent companies operating in markets where hydrofluorocarbon regulations apply, or for facilities pursuing LEED or BREEAM certification, the environmental distinction is significant. Multi Goals recommends Novec 1230 for any project where the client has stated sustainability commitments or international environmental compliance obligations.

Room Integrity Testing, The Mandatory Commissioning Step

Room integrity testing is required by NFPA 2001 for every clean agent suppression system before Saudi Civil Defense acceptance. A calibrated door fan unit installed in the protected space entrance is used to pressurise the enclosure and measure total leakage area. The measured leakage is used to calculate the predicted agent hold time after discharge. NFPA 2001 requires the enclosure to retain agent at or above the minimum extinguishing concentration for a minimum of ten minutes post-discharge. Multi Goals includes room integrity testing as a standard commissioning step on every Novec 1230 project.

Room Integrity Testing, The Mandatory Commissioning Step
Environmental Profile, Why It Matters in Saudi Arabia

Novec 1230 versus FM200 for Saudi Arabia Projects

Both agents deliver equivalent fire suppression performance and both are accepted by Saudi Civil Defense. The key differences are environmental profile, agent volume per protected cubic metre, and cylinder count. Novec 1230 requires slightly less agent by weight for the same protected volume. FM200 has an established cylinder recharge network across Saudi Arabia with a longer track record in the local market. For organisations without environmental sustainability constraints, FM200 remains a strong choice. For those with ESG obligations or green building targets, Novec 1230 is the preferred specification. Multi Goals provides a written comparison of both options in every clean agent project proposal. Related keywords: fire suppression system, clean agent, gas suppression, FK-5-1-12.

Frequently Asked Questions

Novec 1230 uses FK-5-1-12 fluid to suppress fire through heat extraction. It has a Global Warming Potential of 1 and an atmospheric lifetime of approximately five days, compared to FM200 which has a GWP of 3,350 and an atmospheric lifetime of 31 to 40 years. Both agents provide equivalent fire suppression performance and are accepted by Saudi Civil Defense.

Yes. Novec 1230 does not significantly reduce oxygen levels at design suppression concentrations and is classified as safe for occupied spaces. The mandatory 30-second pre-discharge alarm under NFPA 2001 gives occupants time to evacuate before agent discharge begins.

Room integrity testing verifies the protected enclosure retains Novec 1230 at or above the minimum extinguishing concentration for at least ten minutes after discharge, as required by NFPA 2001. An enclosure with excessive leakage from unsealed cable penetrations or non-sealing doors will fail to maintain the required concentration regardless of how correctly the system was designed.

Yes. Novec 1230 suppression systems designed to NFPA 2001 are accepted by Saudi Civil Defense for data centres, server rooms, control rooms, and other qualifying protected spaces across Saudi Arabia.

Yes. We design and install Novec 1230 suppression systems across all regions of Saudi Arabia from our Al Khobar headquarters, with room integrity testing included as standard on every project.

Contact Us

Contact Multi Goals for Novec 1230 suppression system design and installation anywhere in Saudi Arabia.
We include a written FM200 versus Novec 1230 comparison in every clean agent proposal so you can make
an informed specification decision.